{"id":12480,"date":"2026-08-15T17:54:20","date_gmt":"2026-08-15T17:54:20","guid":{"rendered":"https:\/\/www.krlpower.com\/?p=12480"},"modified":"2026-08-15T17:54:20","modified_gmt":"2026-08-15T17:54:20","slug":"industrial-ups-battery-backup-180kva-airport","status":"publish","type":"post","link":"https:\/\/www.krlpower.com\/fr\/bess\/industrial-ups-battery-backup-180kva-airport\/","title":{"rendered":"Syst\u00e8me d'alimentation de secours industriel par onduleur pour des charges a\u00e9roportuaires de 180 kVA"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"12480\" class=\"elementor elementor-12480\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a840141 auto-article-root e-flex e-con-boxed e-con e-parent\" data-id=\"a840141\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ed75b289 auto-image elementor-widget elementor-widget-image\" data-id=\"ed75b289\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-South-Africa-Airport-UPS-180kVA-Cover-1024x576.jpg\" class=\"attachment-large size-large wp-image-12477\" alt=\"Armoire KRL-B522L et onduleur en ligne de 180 kVA install\u00e9s dans un local technique s\u00e9curis\u00e9 d&#039;un a\u00e9roport sud-africain, d&#039;o\u00f9 l&#039;on peut admirer, \u00e0 travers des vitres prot\u00e9g\u00e9es, le paysage c\u00f4t\u00e9 piste du Highveld\" srcset=\"https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-South-Africa-Airport-UPS-180kVA-Cover-1024x576.jpg 1024w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-South-Africa-Airport-UPS-180kVA-Cover-300x169.jpg 300w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-South-Africa-Airport-UPS-180kVA-Cover-768x432.jpg 768w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-South-Africa-Airport-UPS-180kVA-Cover-600x338.jpg 600w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-South-Africa-Airport-UPS-180kVA-Cover.jpg 1400w\" sizes=\"(max-width: 1024px) 100vw, 1024px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-94e9a411 auto-p elementor-widget elementor-widget-heading\" data-id=\"94e9a411\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dans le cadre du projet d'alimentation sans coupure (UPS) en int\u00e9rieur d'un a\u00e9roport sud-africain, la plateforme de stockage d'\u00e9nergie propos\u00e9e par KRL Power est la <strong><a href=\"https:\/\/www.krlpower.com\/fr\/battery\/krl-b522l-250kw-522kwh\/\" target=\"_blank\" style=\"color:#046bd2\">Syst\u00e8me de stockage d'\u00e9nergie \u00e0 refroidissement liquide KRL-B522L, 250 kW \/ 522 kWh<\/a><\/strong>. The customer has specified a 180 kVA three-phase airport load, a 380&#x2013;415 Vac supply, a vertical cabinet layout, SABS safety evidence, engineering drawings, authentic product photographs, and a one-year whole-system warranty. The B522L's published 250 kW AC rating, 400\/230 Vac AC specification, and 375 A maximum AC current form a credible power basis for that request.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-50d20bf9 auto-p elementor-widget elementor-widget-heading\" data-id=\"50d20bf9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le lot livr\u00e9 pour l'a\u00e9roport doit comprendre une armoire KRL-B522L, un onduleur en ligne de 180 kVA portant cette r\u00e9f\u00e9rence, un \u00e9quipement de d\u00e9rivation statique, un \u00e9quipement de d\u00e9rivation de maintenance, un syst\u00e8me de distribution des charges prot\u00e9g\u00e9es, ainsi qu'un dossier technique d\u00e9finissant les responsabilit\u00e9s sur l'ensemble du circuit d'alimentation. L'armoire KRL assure la fonction de stockage d'\u00e9nergie et la couche PCS bidirectionnelle. L'onduleur en ligne fournit une alimentation conditionn\u00e9e en continu au bus critique de l'a\u00e9roport.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-57350650 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"57350650\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">h2 Configuration propos\u00e9e du produit<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-12e3e0b0 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"12e3e0b0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"ceai-table-wrap\" role=\"region\" aria-label=\"Tableau de donn\u00e9es d\u00e9filable\" tabindex=\"0\" data-columns=\"3\"><table><thead><tr><th scope=\"col\">Exigences du client<\/th><th scope=\"col\">Proposition de r\u00e9ponse concernant le mat\u00e9riel<\/th><th scope=\"col\">Publi\u00e9 sur la base KRL<\/th><\/tr><\/thead><tbody><tr><td>Charge a\u00e9roportuaire triphas\u00e9e de 180 kVA<\/td><td>Le KRL-B522L, plateforme de stockage et de conversion de puissance de 250 kW, associ\u00e9e \u00e0 un onduleur en ligne d'une puissance nominale de 180 kVA<\/td><td>Puissance nominale CA de 250 kW (raccord\u00e9 au r\u00e9seau \/ hors r\u00e9seau)<\/td><\/tr><tr><td>380&#x2013;415 Vac supply<\/td><td>Conception d'un syst\u00e8me triphas\u00e9 de 400 V CA avec protection adapt\u00e9e au projet et dimensionnement des c\u00e2bles<\/td><td>400\/230 V CA ; 50\/60 Hz<\/td><\/tr><tr><td>Installation verticale en int\u00e9rieur<\/td><td>Une armoire verticale install\u00e9e dans un local technique d\u00e9di\u00e9, dot\u00e9 d'un acc\u00e8s et d'un agencement d'entretien conformes aux normes<\/td><td>2,480 &#xD7; 1,400 &#xD7; 2,050 mm; approx. 4,900 kg<\/td><\/tr><tr><td>Fonctionnement en alimentation sans coupure (UPS)<\/td><td>Les onduleurs en ligne et le contournement statique alimentent le bus critique ; le B522L prend en charge la couche de stockage et la couche PCS.<\/td><td>Temps de commutation annonc\u00e9 : &lt; 10 ms<\/td><\/tr><tr><td>\u00c9l\u00e9ments de preuve SABS<\/td><td>Registre des certificats et des documents d'essai correspondant pr\u00e9cis\u00e9ment \u00e0 l'ensemble d'\u00e9quipements propos\u00e9<\/td><td>Aucun certificat SABS n'appara\u00eet sur la page publique consacr\u00e9e au B522L.<\/td><\/tr><tr><td>Garantie d'un an sur l'ensemble du syst\u00e8me<\/td><td>Une matrice unique de p\u00e9rim\u00e8tre et d'escalade couvrant les syst\u00e8mes BESS, UPS, le contournement, les commandes et la mise en service<\/td><td>Exigences commerciales du client<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-180859b5 auto-p elementor-widget elementor-widget-heading\" data-id=\"180859b5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le B522L offre une marge de puissance nominale sup\u00e9rieure \u00e0 celle des enceintes de 125 kW de KRL. Un seul <strong><a href=\"https:\/\/www.krlpower.com\/fr\/battery\/krl-b261l-125kw-261kwh\/\" target=\"_blank\" style=\"color:#046bd2\">KRL-B261L, installation de 125 kW \/ 261 kWh<\/a><\/strong> ou <strong><a href=\"https:\/\/www.krlpower.com\/fr\/battery\/krl-125kw-241kwh-bess\/\" target=\"_blank\" style=\"color:#046bd2\">KRL-B241 : syst\u00e8me de 125 kW \/ 241 kWh<\/a><\/strong> sa puissance nominale en courant alternatif est de 125 kW, ce qui est inf\u00e9rieur \u00e0 une charge de 180 kW avec un facteur de puissance unitaire. Le B522L de 250 kW dispose d'une marge nominale de 70 kW \u00e0 ce point de charge.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6d19ef83 auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"6d19ef83\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Syst\u00e8me de stockage KRL et plateforme PCS propos\u00e9s : KRL-B522L, 250 kW \/ 522 kWh.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Couche d'onduleur requise : un onduleur en ligne d'une puissance sp\u00e9cifi\u00e9e de 180 kVA, dont le fabricant, le mod\u00e8le et la courbe de surcharge doivent \u00eatre indiqu\u00e9s dans le devis.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Circuit de continuit\u00e9 requis : d\u00e9rivation statique et d\u00e9rivation de maintenance, avec une s\u00e9quence de fonctionnement homologu\u00e9e.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Documentation de livraison requise : un sch\u00e9ma final d'une ligne repr\u00e9sentant le r\u00e9seau, le syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS), l'onduleur (UPS), le contournement, l'interface du g\u00e9n\u00e9rateur et le bus de l'a\u00e9roport prot\u00e9g\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Donn\u00e9es commerciales requises : un titulaire de garantie et une proc\u00e9dure d'escalade pour l'ensemble du syst\u00e8me d'alimentation \u00e9lectrique de l'a\u00e9roport.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec67f74b elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"ec67f74b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijc5MSIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Demander une offre pour un onduleur KRL 180 kVA destin\u00e9 \u00e0 un a\u00e9roport<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-61ba1ff2 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"61ba1ff2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">h2 Confirm the Power Match at 380&#x2013;415 Vac<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bae556d3 auto-p elementor-widget elementor-widget-heading\" data-id=\"bae556d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La demande de 180 kVA de l'a\u00e9roport d\u00e9termine la puissance apparente requise. La puissance active d\u00e9pend du facteur de puissance mesur\u00e9 de la charge. Avec un facteur de puissance de 0,80, la charge prot\u00e9g\u00e9e est de 144 kW. Avec un facteur de puissance de 0,90, elle est de 162 kW. Avec un facteur de puissance unitaire, elle est de 180 kW. Chaque point de fonctionnement reste dans les limites de la puissance nominale de 250 kW CA indiqu\u00e9e pour le B522L.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3ca9e151 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"3ca9e151\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"ceai-table-wrap\" role=\"region\" aria-label=\"Tableau de donn\u00e9es d\u00e9filable\" tabindex=\"0\" data-columns=\"4\"><table><thead><tr><th scope=\"col\">Condition de charge de 180 kVA<\/th><th scope=\"col\">Puissance active<\/th><th scope=\"col\">Courant de ligne approximatif dans un r\u00e9seau triphas\u00e9 de 400 V CA<\/th><th scope=\"col\">R\u00e9f\u00e9rence AC publi\u00e9e pour le B522L<\/th><\/tr><\/thead><tbody><tr><td>facteur de puissance de 0,80<\/td><td>144 kW<\/td><td>260 A<\/td><td>250 kW ; courant alternatif maximal de 375 A<\/td><\/tr><tr><td>facteur de puissance de 0,90<\/td><td>162 kW<\/td><td>260 A<\/td><td>250 kW ; courant alternatif maximal de 375 A<\/td><\/tr><tr><td>Facteur de puissance de 1,00<\/td><td>180 kW<\/td><td>260 A<\/td><td>250 kW ; courant alternatif maximal de 375 A<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ae5efea8 auto-p elementor-widget elementor-widget-heading\" data-id=\"ae5efea8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La valeur de 260 A est calcul\u00e9e \u00e0 partir d'une puissance de 180 kVA \u00e0 400 V CA dans un r\u00e9seau triphas\u00e9. La conception \u00e9lectrique n\u00e9cessite encore la confirmation par l'a\u00e9roport du niveau de d\u00e9faut, de l'intensit\u00e9 de court-circuit admissible, de la coordination des dispositifs de protection, de la configuration du neutre, du syst\u00e8me de mise \u00e0 la terre et du trac\u00e9 des c\u00e2bles d'alimentation. Les chiffres publics du KRL d\u00e9terminent la classe du produit ; le plan d\u00e9finitif garantit une installation en toute s\u00e9curit\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4c1e81b7 auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"4c1e81b7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Pr\u00e9cisez une puissance nominale en continu de l'onduleur de 180 kVA ou plus et indiquez la dur\u00e9e de surcharge dans l'offre.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">R\u00e9glez la limite de fonctionnement du BESS\/PCS en fonction de la demande en kW approuv\u00e9e pour l'a\u00e9roport et du r\u00e9gime d'alimentation s\u00e9lectionn\u00e9 pour l'onduleur.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">S\u00e9parer les \u00e9quipements essentiels, pour lesquels la tol\u00e9rance de transfert est faible, des \u00e9quipements n\u00e9cessitant une alimentation UPS v\u00e9ritablement en ligne.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u00c9vitez de connecter le d\u00e9marrage des moteurs et les variations importantes de charge au bus de l'onduleur prot\u00e9g\u00e9 jusqu\u2019\u00e0 ce que les rapports de test de l\u2019onduleur et du syst\u00e8me de stockage d\u2019\u00e9nergie (BESS) s\u00e9lectionn\u00e9s confirment que le syst\u00e8me est capable de supporter cette charge.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Int\u00e9grer les r\u00e9glages de protection et les verrouillages de contournement dans la proc\u00e9dure d'essais de mise en service.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-372639e1 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"372639e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">h2 \u00c9valuation de l'autonomie de la batterie sur le bus de l'a\u00e9roport prot\u00e9g\u00e9<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8566cfd1 auto-p elementor-widget elementor-widget-heading\" data-id=\"8566cfd1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La fiche technique publique du mod\u00e8le KRL-B522L indique une capacit\u00e9 nominale de batterie de 522 kWh. Le bon de commande de l\u2019a\u00e9roport doit pr\u00e9ciser une autonomie garantie en courant alternatif \u00e0 la sortie de l\u2019onduleur prot\u00e9g\u00e9. Le calcul doit tenir compte de la conversion du syst\u00e8me de contr\u00f4le de puissance (PCS), de la conversion de l\u2019onduleur, de la consommation auxiliaire, de la marge de temp\u00e9rature, de la plage d\u2019\u00e9tat de charge utilisable et de la marge de capacit\u00e9. Cela permet de lier la valeur de l\u2019\u00e9nergie de la batterie \u00e0 une mission op\u00e9rationnelle v\u00e9rifiable de l\u2019a\u00e9roport.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-322a6d0a auto-table elementor-widget elementor-widget-text-editor\" data-id=\"322a6d0a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"ceai-table-wrap\" role=\"region\" aria-label=\"Tableau de donn\u00e9es d\u00e9filable\" tabindex=\"0\" data-columns=\"4\"><table><thead><tr><th scope=\"col\">Point de charge prot\u00e9g\u00e9<\/th><th scope=\"col\">Consommation \u00e9lectrique du climatiseur pendant 30 minutes<\/th><th scope=\"col\">Consommation \u00e9lectrique en courant alternatif pendant 60 minutes<\/th><th scope=\"col\">120 minutes d'\u00e9nergie CA<\/th><\/tr><\/thead><tbody><tr><td>144 kW avec un facteur de puissance de 0,80<\/td><td>72 kWh<\/td><td>144 kWh<\/td><td>288 kWh<\/td><\/tr><tr><td>162 kW avec un facteur de puissance de 0,90<\/td><td>81 kWh<\/td><td>162 kWh<\/td><td>324 kWh<\/td><\/tr><tr><td>180 kW avec un facteur de puissance unitaire<\/td><td>90 kWh<\/td><td>180 kWh<\/td><td>360 kWh<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-772dbad8 auto-p elementor-widget elementor-widget-heading\" data-id=\"772dbad8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Par exemple, une charge prot\u00e9g\u00e9e de 162 kW n\u00e9cessite 162 kWh au niveau du bus CA pour un temps de fonctionnement de 60 minutes, avant conversion et marges d'exploitation. Le fournisseur doit pr\u00e9senter le calcul depuis la charge de l'a\u00e9roport jusqu'\u00e0 la batterie, en passant par l'onduleur (UPS) et le syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS). KRL's <strong><a href=\"https:\/\/www.krlpower.com\/fr\/bess\/battery-backup-for-power-outages-commercial-ess\/\" target=\"_blank\" style=\"color:#046bd2\">Guide sur les syst\u00e8mes d'alimentation de secours \u00e0 batterie \u00e0 usage commercial<\/a><\/strong> peut \u00e9tayer le d\u00e9bat sur la charge critique requise et la r\u00e9silience face aux pannes.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b89e82a2 auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"b89e82a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Indiquez la dur\u00e9e de fonctionnement garantie \u00e0 la puissance nominale contractuelle de 180 kVA et \u00e0 la puissance de charge critique mesur\u00e9e en kW.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">D\u00e9finissez l'\u00e9tat de charge initial et les conditions de fin d'essai.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Pr\u00e9cisez quelles charges auxiliaires sont prises en compte dans le r\u00e9sultat de fonctionnement.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Consigner les conditions ambiantes de fonctionnement utilis\u00e9es pour l'essai de r\u00e9ception.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">R\u00e9p\u00e9tez la m\u00eame op\u00e9ration que celle d\u00e9crite dans le cadre du test de capacit\u00e9 de la garantie d'un an.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5fdb8308 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"5fdb8308\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">h2 Int\u00e9grer l'onduleur, le circuit de d\u00e9rivation et l'interface BESS au sein d'un seul ensemble \u00e9lectrique<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-03bb479c auto-image elementor-widget elementor-widget-image\" data-id=\"03bb479c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Airport-UPS-Interface-Review-1024x576.jpg\" class=\"attachment-large size-large wp-image-12478\" alt=\"Armoire KRL-B522L \u00e0 c\u00f4t\u00e9 d&#039;un tableau de contr\u00f4le d&#039;interface pr\u00e9sentant le r\u00e9seau, un onduleur en ligne de 180 kVA, un bypass statique, un bus critique, un g\u00e9n\u00e9rateur et le KRL-B522L\" srcset=\"https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Airport-UPS-Interface-Review-1024x576.jpg 1024w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Airport-UPS-Interface-Review-300x169.jpg 300w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Airport-UPS-Interface-Review-768x432.jpg 768w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Airport-UPS-Interface-Review-600x338.jpg 600w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Airport-UPS-Interface-Review.jpg 1400w\" sizes=\"(max-width: 1024px) 100vw, 1024px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-43ee6134 auto-p elementor-widget elementor-widget-heading\" data-id=\"43ee6134\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le B522L assure les fonctions de stockage d'\u00e9nergie et de syst\u00e8me de conversion de puissance (PCS). Un onduleur (UPS) en ligne assure une alimentation \u00e9lectrique ininterrompue et conditionn\u00e9e sur le bus critique de l'a\u00e9roport. Les \u00e9quipements de d\u00e9rivation statique et de d\u00e9rivation de maintenance cr\u00e9ent des voies de contournement s\u00fbres en cas de d\u00e9faillance ou d'intervention de maintenance. La conception doit identifier la fonction et la responsabilit\u00e9 de chaque dispositif et d\u00e9signer un responsable pour chaque point de transfert entre l'armoire KRL et le parc d'onduleurs.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5e4245f1 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"5e4245f1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"ceai-table-wrap\" role=\"region\" aria-label=\"Tableau de donn\u00e9es d\u00e9filable\" tabindex=\"0\" data-columns=\"3\"><table><thead><tr><th scope=\"col\">Limites de l'\u00e9quipement<\/th><th scope=\"col\">D\u00e9cision requise concernant le projet<\/th><th scope=\"col\">Justificatifs requis avant l'exp\u00e9dition<\/th><\/tr><\/thead><tbody><tr><td>KRL-B522L vers l'entr\u00e9e de l'onduleur<\/td><td>M\u00e9thode de raccordement, dispositif d'isolation, c\u00e2ble de puissance nominale, dispositif de protection et commandes<\/td><td>Sch\u00e9ma unifilaire et liste des c\u00e2bles approuv\u00e9s<\/td><\/tr><tr><td>Onduleur en ligne vers le bus critique<\/td><td>Mod\u00e8le d'onduleur, puissance nominale en kVA, courbe de surcharge, disjoncteur de sortie et r\u00e9partition des charges critiques<\/td><td>Fiche technique de l'onduleur et tableau des charges prot\u00e9g\u00e9es<\/td><\/tr><tr><td>Contournement statique et de maintenance<\/td><td>Syst\u00e8me de verrouillage, \u00e9tiquettes, autorisation d'exploitation et proc\u00e9dure de maintenance<\/td><td>S\u00e9quence de d\u00e9rivation et fiche de test fonctionnel en pr\u00e9sence d'un t\u00e9moin<\/td><\/tr><tr><td>Interface du g\u00e9n\u00e9rateur<\/td><td>Signal de d\u00e9marrage, ordre de transfert de charge, acceptation du g\u00e9n\u00e9rateur et s\u00e9quence de retour \u00e0 la normale<\/td><td>Sch\u00e9ma de s\u00e9quence des op\u00e9rations et proc\u00e8s-verbal d'essai sur site<\/td><\/tr><tr><td>Suivi du transfert<\/td><td>Points d'alarme, protocole, destinataires, exportation des \u00e9v\u00e9nements et responsable de l'acc\u00e8s<\/td><td>Liste des points et compte rendu du test de communication<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3a44cf23 auto-p elementor-widget elementor-widget-heading\" data-id=\"3a44cf23\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">KRL's <strong><a href=\"https:\/\/www.krlpower.com\/fr\/bess\/ci-energy-storage-bms-pcs-ems-krl-power\/\" target=\"_blank\" style=\"color:#046bd2\">Informations sur les syst\u00e8mes BMS, PCS et EMS<\/a><\/strong> d\u00e9crit les niveaux de contr\u00f4le concern\u00e9s. Le dossier technique du projet doit inclure le sch\u00e9ma d'E\/S effectif, le protocole de communication, la cartographie des alarmes et les pr\u00e9rogatives de contr\u00f4le pour les \u00e9quipements s\u00e9lectionn\u00e9s.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-465ddb1e elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"465ddb1e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijc5MSIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Demander une \u00e9valuation de l'interface KRL UPS-BESS<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-09888ec2 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"09888ec2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">h2 Installation du KRL-B522L dans la salle int\u00e9rieure de l'a\u00e9roport<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ab28349 auto-p elementor-widget elementor-widget-heading\" data-id=\"1ab28349\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le KRL-B522L mesure environ 2 480 mm de long, 1 400 mm de profondeur et 2 050 mm de hauteur, pour un poids approximatif de 4 900 kg. La conception du local \u00e9lectrique int\u00e9rieur doit permettre d\u2019accueillir cette armoire, la gamme d\u2019onduleurs de 180 kVA, les \u00e9quipements de d\u00e9rivation et les tableaux de charge prot\u00e9g\u00e9e dans une disposition facilitant l\u2019entretien. L\u2019armoire est verticale ; KRL doit confirmer la configuration modulaire d\u00e9taill\u00e9e, le c\u00f4t\u00e9 maintenance et la disposition finale des entr\u00e9es de c\u00e2bles pour la configuration propos\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1265c7c3 auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"1265c7c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Indiquez l'encombrement de l'armoire, les acc\u00e8s de maintenance \u00e0 l'avant et \u00e0 l'arri\u00e8re, ainsi que la zone de maintenance de l'onduleur (UPS) et du contournement sur le plan d'ensemble.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">V\u00e9rifier l'itin\u00e9raire de livraison, la largeur des portes, les virages dans les couloirs, le plan de levage, la charge admissible au sol et la conception du socle pour l'armoire de 4 900 kg.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">D\u00e9finir le circuit d'air de refroidissement, les performances du syst\u00e8me CVC de la pi\u00e8ce, les dispositifs de d\u00e9tection, les \u00e9quipements de protection contre l'incendie et l'emplacement des arr\u00eats d'urgence.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Indiquer le trac\u00e9 des chemins de c\u00e2bles, la s\u00e9paration des c\u00e2bles d'alimentation, les conducteurs de mise \u00e0 la terre, les conducteurs de d\u00e9rivation et le c\u00e2blage de surveillance.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Veillez \u00e0 ce que l'acc\u00e8s technique \u00e0 la salle d'alimentation critique soit contr\u00f4l\u00e9 \u00e0 l'aide d'\u00e9tiquettes sur les \u00e9quipements et d'une signalisation op\u00e9rationnelle.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-93f0af7f auto-p elementor-widget elementor-widget-heading\" data-id=\"93f0af7f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les donn\u00e9es publiques de KRL concernant le mod\u00e8le B522L mentionnent un refroidissement par liquide, un bo\u00eetier de batterie IP65, un syst\u00e8me de refroidissement intelligent PCS et un syst\u00e8me de protection contre les incendies. La page publique ne pr\u00e9cise pas les exigences d'espace libre dans les locaux \u00e9lectriques de l'a\u00e9roport, les chiffres relatifs au rejet de chaleur de ces locaux, ni ne fournit de plan d'installation sud-africain. Ces \u00e9l\u00e9ments rel\u00e8vent des livrables techniques sp\u00e9cifiques au projet. Utilisez les donn\u00e9es de KRL <strong><a href=\"https:\/\/www.krlpower.com\/fr\/bess\/how-to-design-commercial-energy-storage-system\/\" target=\"_blank\" style=\"color:#046bd2\">processus de conception de syst\u00e8mes de stockage d'\u00e9nergie \u00e0 usage commercial<\/a><\/strong> afin de faire correspondre les dimensions du produit avec le sch\u00e9ma d'implantation d\u00e9finitif, le plan de protection et la s\u00e9quence de mise en service.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-45a8ac83 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"45a8ac83\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">h2 Int\u00e9grer les justificatifs SABS, les plans et les photos des produits dans le p\u00e9rim\u00e8tre de livraison<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-df686005 auto-p elementor-widget elementor-widget-heading\" data-id=\"df686005\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La preuve de conformit\u00e9 aux normes SABS constitue une exigence explicite du client. La page publique du produit KRL-B522L ne mentionne pas de certificat SABS. La proposition commerciale doit donc inclure un registre de conformit\u00e9 qui \u00e9tablisse un lien entre chaque certificat, rapport et plan et l'armoire de batteries, le PCS, l'onduleur en ligne, l'\u00e9quipement de d\u00e9rivation et le bo\u00eetier livr\u00e9s \u00e0 l'a\u00e9roport.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-94ffbe11 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"94ffbe11\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"ceai-table-wrap\" role=\"region\" aria-label=\"Tableau de donn\u00e9es d\u00e9filable\" tabindex=\"0\" data-columns=\"3\"><table><thead><tr><th scope=\"col\">\u00c9l\u00e9ment de livraison obligatoire<\/th><th scope=\"col\">L'acheteur de l'a\u00e9roport s'en sert pour v\u00e9rifier<\/th><th scope=\"col\">Condition d'acceptation<\/th><\/tr><\/thead><tbody><tr><td>Registre des \u00e9l\u00e9ments de preuve du SABS<\/td><td>Champ d'application du certificat, identit\u00e9 du mod\u00e8le, norme applicable et dur\u00e9e de validit\u00e9<\/td><td>Chaque document correspond \u00e0 la nomenclature finale<\/td><\/tr><tr><td>Sch\u00e9ma unifilaire \u00e9lectrique<\/td><td>R\u00e9seau, syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS), onduleur (UPS), d\u00e9rivation, groupe \u00e9lectrog\u00e8ne et limites du bus prot\u00e9g\u00e9<\/td><td>La r\u00e9vision du sch\u00e9ma correspond \u00e0 la configuration install\u00e9e<\/td><\/tr><tr><td>Plan d'ensemble<\/td><td>Emplacement dans la pi\u00e8ce, espace de service, cheminement des c\u00e2bles, arr\u00eat d'urgence et voie d'acc\u00e8s<\/td><td>Les dimensions de l'armoire et les conditions sur site sont indiqu\u00e9es<\/td><\/tr><tr><td>Photos authentiques des produits<\/td><td>Format de l'armoire, marquage KRL, c\u00f4t\u00e9 d'acc\u00e8s et configuration de l'\u00e9quipement<\/td><td>Les photos montrent le produit propos\u00e9 et la pr\u00e9sentation finale avant exp\u00e9dition.<\/td><\/tr><tr><td>Plan de mise en service<\/td><td>Rapports relatifs aux essais de puissance, au transfert de l'onduleur, aux essais de d\u00e9rivation, aux essais d'alarme et aux op\u00e9rations de transfert<\/td><td>Les points de contr\u00f4le, les crit\u00e8res d'\u00e9valuation et les crit\u00e8res de r\u00e9ussite sont pr\u00e9cis\u00e9s<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d95f2bd6 auto-p elementor-widget elementor-widget-heading\" data-id=\"d95f2bd6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le dossier photographique du produit doit inclure des vues de face, de profil, de dos et de service, ainsi que les d\u00e9tails d'identification du mod\u00e8le KRL, le sens de passage des c\u00e2bles, les \u00e9quipements de refroidissement, les interfaces de protection incendie, le format de la plaque signal\u00e9tique, l'emballage et la m\u00e9thode de chargement. Ces \u00e9l\u00e9ments permettent \u00e0 l'EPC de comparer la configuration finale avec l'armoire physique avant l'exp\u00e9dition.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ac2de487 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"ac2de487\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">h2 R\u00e9digez la garantie d'un an couvrant l'ensemble du syst\u00e8me Critical-Power<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3b5fee6a auto-p elementor-widget elementor-widget-heading\" data-id=\"3b5fee6a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La garantie d'un an demand\u00e9e doit s'\u00e9tendre \u00e0 tous les composants fournis dans le cadre du contrat a\u00e9roportuaire. Le tableau de garantie doit pr\u00e9ciser les responsabilit\u00e9s concernant l'onduleur, le circuit de d\u00e9rivation, le syst\u00e8me de contr\u00f4le et les interfaces de mise en service. Regroupez tous ces \u00e9l\u00e9ments dans un seul tableau et indiquez \u00e0 l'a\u00e9roport une proc\u00e9dure d'escalade unique.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4e3b9b97 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"4e3b9b97\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"ceai-table-wrap\" role=\"region\" aria-label=\"Tableau de donn\u00e9es d\u00e9filable\" tabindex=\"0\" data-columns=\"3\"><table><thead><tr><th scope=\"col\">\u00c9l\u00e9ment d'emballage<\/th><th scope=\"col\">\u00c9tendue de la garantie requise<\/th><th scope=\"col\">Registre de passation obligatoire<\/th><\/tr><\/thead><tbody><tr><td>Armoire KRL-B522L<\/td><td>Batterie, PCS, BMS, EMS, \u00e9quipements de refroidissement et de protection contre les incendies compris dans l'offre<\/td><td>Donn\u00e9es techniques, num\u00e9ros de s\u00e9rie, r\u00e9glages et instructions d'entretien<\/td><\/tr><tr><td>Onduleur en ligne de 180 kVA<\/td><td>Redresseur, onduleur, d\u00e9rivation statique, commandes et surveillance<\/td><td>Rapport d'essai de l'onduleur, essai de d\u00e9rivation et sauvegarde des param\u00e8tres<\/td><\/tr><tr><td>\u00c9quipements de d\u00e9rivation et de distribution<\/td><td>Appareillage de commande, disjoncteurs, dispositifs de verrouillage, compteurs, c\u00e2blage et \u00e9tiquettes compris dans la fourniture<\/td><td>Param\u00e8tres de protection et plans de conformit\u00e9<\/td><\/tr><tr><td>Commandes et communications<\/td><td>Mappage des alarmes, liste des points, passerelle de protocole et configuration de l'acc\u00e8s<\/td><td>Rapport de test de communication point \u00e0 point<\/td><\/tr><tr><td>Mise en service et intervention technique<\/td><td>Tests fonctionnels, formation, notification des dysfonctionnements, diagnostic et proc\u00e9dure de mesures correctives<\/td><td>Documents sign\u00e9s relatifs \u00e0 l'acceptation, \u00e0 la formation et \u00e0 la remont\u00e9e d'incidents<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-57ba7863 auto-p elementor-widget elementor-widget-heading\" data-id=\"57ba7863\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le cahier des charges de garantie doit pr\u00e9ciser la date de d\u00e9but de la garantie, les conditions d'exploitation approuv\u00e9es, la m\u00e9thode de test de capacit\u00e9, l'engagement en mati\u00e8re de d\u00e9lai d'intervention, le circuit d'approvisionnement en pi\u00e8ces de rechange, la prise en charge des frais de d\u00e9placement, l'acc\u00e8s aux donn\u00e9es d'alarme et les contacts en cas d'escalade. KRL's <strong><a href=\"https:\/\/www.krlpower.com\/fr\/bess\/how-to-choose-commercial-energy-storage-system\/\" target=\"_blank\" style=\"color:#046bd2\">Guide de s\u00e9lection des syst\u00e8mes de stockage d'\u00e9nergie \u00e0 usage commercial<\/a><\/strong> peut faciliter la comparaison finale entre les limites de la garantie, les engagements en mati\u00e8re de dur\u00e9e de fonctionnement, l'agencement du site et les responsabilit\u00e9s li\u00e9es au syst\u00e8me.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7a255b27 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"7a255b27\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">h2 Mise en \u0153uvre du \u00ab paquet a\u00e9roportuaire \u00bb en fonction des r\u00e9sultats mesur\u00e9s<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-45860725 auto-image elementor-widget elementor-widget-image\" data-id=\"45860725\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Airport-UPS-Acceptance-Handover-1024x576.jpg\" class=\"attachment-large size-large wp-image-12479\" alt=\"Armoire KRL-B522L \u00e0 c\u00f4t\u00e9 d&#039;un analyseur de qualit\u00e9 d&#039;alimentation affichant 400 Vca, 260 A et 180 kVA lors de la mise en service de l&#039;onduleur de l&#039;a\u00e9roport et de la remise de la documentation\" srcset=\"https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Airport-UPS-Acceptance-Handover-1024x576.jpg 1024w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Airport-UPS-Acceptance-Handover-300x169.jpg 300w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Airport-UPS-Acceptance-Handover-768x432.jpg 768w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Airport-UPS-Acceptance-Handover-600x338.jpg 600w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Airport-UPS-Acceptance-Handover.jpg 1400w\" sizes=\"(max-width: 1024px) 100vw, 1024px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d56aa953 auto-p elementor-widget elementor-widget-heading\" data-id=\"d56aa953\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L\u2019\u00e9quipe charg\u00e9e de la mise en service doit tester la charge r\u00e9elle de l\u2019a\u00e9roport ou un banc de charge \u00e9quivalent document\u00e9. Le rapport d\u2019essai doit indiquer les donn\u00e9es de fonctionnement \u00e0 400 V CA, le courant, la puissance en kW et en kVA, le facteur de puissance, la qualit\u00e9 de sortie de l\u2019onduleur (UPS), l\u2019\u00e9tat de fonctionnement du syst\u00e8me de stockage d\u2019\u00e9nergie par batterie (BESS), la fonction de d\u00e9rivation, les alarmes, la s\u00e9quence de d\u00e9marrage du g\u00e9n\u00e9rateur et la dur\u00e9e totale de l\u2019alimentation de secours. Un dossier de transfert sign\u00e9 \u00e9tablit que le syst\u00e8me fourni est un actif op\u00e9rationnel dont la responsabilit\u00e9 est clairement attribu\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f4ce3d65 auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"f4ce3d65\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Sch\u00e9ma unifilaire sign\u00e9 et plan d'agencement g\u00e9n\u00e9ral d\u00e9finitif.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Fiche technique du mod\u00e8le KRL-B522L, num\u00e9ros de s\u00e9rie et photos du produit avant exp\u00e9dition.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Rapports de tests fonctionnels de l'onduleur (UPS), du bypass statique et du bypass de maintenance.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Test d'autonomie de la batterie avec condition de d\u00e9part, charge mesur\u00e9e, dur\u00e9e et condition de fin.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Param\u00e8tres de protection, param\u00e8tres du contr\u00f4leur, versions du micrologiciel et liste des points de communication.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Registre des justificatifs SABS associ\u00e9 \u00e0 l'\u00e9quipement final livr\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Tableau r\u00e9capitulatif de la garantie d'un an couvrant l'ensemble du syst\u00e8me, coordonn\u00e9es du service apr\u00e8s-vente et proc\u00e9dure d'escalade.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0aaff402 auto-p elementor-widget elementor-widget-heading\" data-id=\"0aaff402\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour une pr\u00e9sentation compl\u00e8te de l'offre de stockage C&amp;I, l'acheteur peut consulter <strong><a href=\"https:\/\/www.krlpower.com\/fr\/piles\/ci-energy-storage-system\/\" target=\"_blank\" style=\"color:#046bd2\">Syst\u00e8mes de stockage d'\u00e9nergie KRL Power C&amp;I<\/a><\/strong> et soumettre la configuration requise par l'a\u00e9roport via KRL Power\u2019s <strong><a href=\"https:\/\/www.krlpower.com\/fr\/contact-us\/\" target=\"_blank\" style=\"color:#046bd2\">canal d\u00e9di\u00e9 aux demandes techniques<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bf339671 elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"bf339671\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijc5MSIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Demander les plans, les photos du produit et les conditions de garantie du mod\u00e8le KRL-B522L<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-48a0e21f auto-h2 elementor-widget elementor-widget-heading\" data-id=\"48a0e21f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">h2 FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6c890cf6 e-con-full auto-faq e-flex e-con e-child\" data-id=\"6c890cf6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d36d6906 elementor-widget elementor-widget-heading\" data-id=\"d36d6906\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b30ff468 elementor-widget elementor-widget-n-accordion\" data-id=\"b30ff468\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings='{\"default_state\":\"all_collapsed\",\"max_items_expended\":\"one\",\"n_accordion_animation_duration\":{\"unit\":\"ms\",\"size\":400,\"sizes\":[]}}' data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les \u00e0 l&#039;aide de la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3000\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3000\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> Quel produit KRL est propos\u00e9 pour le projet d'onduleur de 180 kVA destin\u00e9 \u00e0 l'a\u00e9roport ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3000\" class=\"elementor-element elementor-element-665bcaf8 e-con-full e-flex e-con e-child\" data-id=\"665bcaf8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6466c2f6 elementor-widget elementor-widget-heading\" data-id=\"6466c2f6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La solution de stockage KRL et la plateforme PCS propos\u00e9es sont le mod\u00e8le KRL-B522L, que KRL pr\u00e9sente comme un syst\u00e8me tout-en-un \u00e0 refroidissement liquide d'une puissance de 250 kW et d'une capacit\u00e9 de 522 kWh. L'offre destin\u00e9e \u00e0 l'a\u00e9roport comprend \u00e9galement un onduleur en ligne d'une puissance nominale de 180 kVA et un \u00e9quipement de d\u00e9rivation.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3001\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3001\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> Un seul KRL-B522L peut-il prendre en charge une charge a\u00e9roportuaire de 180 kVA ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3001\" class=\"elementor-element elementor-element-9fc8a545 e-con-full e-flex e-con e-child\" data-id=\"9fc8a545\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-02457683 elementor-widget elementor-widget-heading\" data-id=\"02457683\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">KRL publishes a 250 kW AC rating and 375 A maximum AC current for the B522L. A 180 kVA load equals 144&#x2013;180 kW across power factors from 0.80 to 1.00, so the stated load falls within the B522L's published 250 kW AC rating. The final design must verify load steps, overload duty, and protection coordination.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3002\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3002\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> Does the KRL-B522L match a 380&#x2013;415 Vac three-phase supply? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3002\" class=\"elementor-element elementor-element-d2d7f6ec e-con-full e-flex e-con e-child\" data-id=\"d2d7f6ec\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-182c15d5 elementor-widget elementor-widget-heading\" data-id=\"182c15d5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">KRL indique une tension de 400\/230 V CA et une fr\u00e9quence de 50\/60 Hz pour le mod\u00e8le B522L. Le projet d\u00e9finitif de l'a\u00e9roport doit pr\u00e9ciser la tension nominale, la tol\u00e9rance autoris\u00e9e, les caract\u00e9ristiques nominales des disjoncteurs, le dimensionnement des c\u00e2bles, le sch\u00e9ma de mise \u00e0 la terre et le mod\u00e8le d'onduleur retenu.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3003\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3003\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> Quelle autonomie de secours 522 kWh peuvent-ils offrir pour la charge d'un onduleur d'a\u00e9roport ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3003\" class=\"elementor-element elementor-element-56c1642c e-con-full e-flex e-con e-child\" data-id=\"56c1642c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d23be555 elementor-widget elementor-widget-heading\" data-id=\"d23be555\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">\u00c0 162 kW, une utilisation de 60 minutes au niveau du bus CA n\u00e9cessite 162 kWh avant conversion et marges de fonctionnement. L'offre commerciale doit pr\u00e9ciser une autonomie garantie en CA apr\u00e8s prise en compte des pertes du PCS et de l'onduleur, de la charge auxiliaire, de la plage de fonctionnement et de la marge de capacit\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3004\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3004\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> Pourquoi le projet n\u00e9cessite-t-il un onduleur en ligne en plus du KRL-B522L ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3004\" class=\"elementor-element elementor-element-00053513 e-con-full e-flex e-con e-child\" data-id=\"00053513\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b1d254b6 elementor-widget elementor-widget-heading\" data-id=\"b1d254b6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le KRL-B522L assure les fonctions de stockage d'\u00e9nergie et de syst\u00e8me de conversion de puissance (PCS). Un onduleur (UPS) en ligne d\u00e9sign\u00e9 fournit une alimentation conditionn\u00e9e en continu aux circuits sensibles de l'a\u00e9roport. Des \u00e9quipements de d\u00e9rivation statique et de maintenance assurent des voies de contournement contr\u00f4l\u00e9es en cas de panne ou d'intervention de maintenance.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3005\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3005\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> La soci\u00e9t\u00e9 KRL publie-t-elle un chiffre concernant la commutation pour le mod\u00e8le B522L ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3005\" class=\"elementor-element elementor-element-91b2cc20 e-con-full e-flex e-con e-child\" data-id=\"91b2cc20\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c15cdd29 elementor-widget elementor-widget-heading\" data-id=\"c15cdd29\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les informations publiques de KRL concernant le mod\u00e8le B522L indiquent un temps de commutation inf\u00e9rieur \u00e0 10 ms. Le bus critique de l'a\u00e9roport doit \u00eatre aliment\u00e9 par un onduleur s\u00e9lectionn\u00e9 en ligne, lorsque la charge n\u00e9cessite une sortie conditionn\u00e9e continue et sans interruption.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3006\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3006\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> La page publique KRL-B522L fournit-elle un certificat SABS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3006\" class=\"elementor-element elementor-element-9b479b64 e-con-full e-flex e-con e-child\" data-id=\"9b479b64\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cad674ec elementor-widget elementor-widget-heading\" data-id=\"cad674ec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Aucun certificat SABS n'appara\u00eet sur la page publique consacr\u00e9e au mod\u00e8le KRL-B522L. Le devis doit inclure un registre des certificats et des rapports d'essai pr\u00e9cisant les mod\u00e8les exacts du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS), de l'onduleur (UPS) et des \u00e9quipements de d\u00e9rivation, ainsi que la nomenclature d\u00e9finitive des composants fournis \u00e0 l'a\u00e9roport.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3007\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3007\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> Quelles sont les caract\u00e9ristiques techniques de l'unit\u00e9 int\u00e9rieure applicables au mod\u00e8le KRL-B522L ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3007\" class=\"elementor-element elementor-element-6c686aff e-con-full e-flex e-con e-child\" data-id=\"6c686aff\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6e4cdd0a elementor-widget elementor-widget-heading\" data-id=\"6e4cdd0a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">KRL publishes approximate dimensions of 2,480 &#xD7; 1,400 &#xD7; 2,050 mm and a weight of approximately 4,900 kg. The project drawing should show service space, access route, floor loading, HVAC, cable route, detection, fire protection and emergency-stop positions.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3008\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3008\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> Le syst\u00e8me propos\u00e9 r\u00e9pond-il \u00e0 l'exigence de conception modulaire verticale ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3008\" class=\"elementor-element elementor-element-dc2981b4 e-con-full e-flex e-con e-child\" data-id=\"dc2981b4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-50c9f379 elementor-widget elementor-widget-heading\" data-id=\"50c9f379\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le mod\u00e8le B522L est une armoire verticale. KRL doit confirmer, dans les plans techniques, les d\u00e9tails relatifs \u00e0 la conception modulaire, au c\u00f4t\u00e9 maintenance, \u00e0 l'entr\u00e9e des c\u00e2bles et \u00e0 la disposition finale de l'armoire pour la configuration a\u00e9roportuaire propos\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3009\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3009\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> Que doit couvrir la garantie d'un an sur l'ensemble du syst\u00e8me ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3009\" class=\"elementor-element elementor-element-1d4885de e-con-full e-flex e-con e-child\" data-id=\"1d4885de\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8a1fbc6d elementor-widget elementor-widget-heading\" data-id=\"8a1fbc6d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Il convient d'y pr\u00e9ciser les responsabilit\u00e9s en mati\u00e8re de garantie concernant le syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS), le syst\u00e8me de contr\u00f4le de puissance (PCS), le syst\u00e8me de gestion de batterie (BMS), le syst\u00e8me de gestion d'\u00e9nergie (EMS), le syst\u00e8me de refroidissement, la protection incendie, l'onduleur en ligne (UPS), le contournement statique, le contournement de maintenance, les \u00e9quipements de distribution, les syst\u00e8mes de commande, la mise en service et la remont\u00e9e des incidents.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-30010\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-30010\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> Pourquoi l'EPC devrait-il demander des photos authentiques des produits KRL ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-30010\" class=\"elementor-element elementor-element-f6148fe1 e-con-full e-flex e-con e-child\" data-id=\"f6148fe1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-feddf3e0 elementor-widget elementor-widget-heading\" data-id=\"feddf3e0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les photos actuelles des produits permettent \u00e0 l'EPC de v\u00e9rifier, avant l'exp\u00e9dition, les dimensions de l'armoire, l'identification du mod\u00e8le KRL, le c\u00f4t\u00e9 d'intervention, l'entr\u00e9e de c\u00e2bles, l'\u00e9quipement de refroidissement, la m\u00e9thode de levage et l'ad\u00e9quation \u00e0 l'espace pr\u00e9vu. Le dossier final doit inclure des photos prises avant l'exp\u00e9dition montrant la configuration propos\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-30011\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-30011\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> Le KRL-B522L peut-il \u00eatre raccord\u00e9 \u00e0 un g\u00e9n\u00e9rateur d'a\u00e9roport ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-30011\" class=\"elementor-element elementor-element-940486cb e-con-full e-flex e-con e-child\" data-id=\"940486cb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7246af4d elementor-widget elementor-widget-heading\" data-id=\"7246af4d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">KRL mentionne une interface de g\u00e9n\u00e9rateur pour le B522L. Le dossier de l'a\u00e9roport doit d\u00e9finir la commande de d\u00e9marrage du g\u00e9n\u00e9rateur, l'ordre de transfert de charge, la m\u00e9thode de synchronisation, les r\u00e9glages des dispositifs de protection et la s\u00e9quence de retour \u00e0 la normale.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-30012\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-30012\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> Quels documents l'a\u00e9roport doit-il recevoir lors de sa mise en service ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-30012\" class=\"elementor-element elementor-element-41163e55 e-con-full e-flex e-con e-child\" data-id=\"41163e55\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-80687053 elementor-widget elementor-widget-heading\" data-id=\"80687053\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La remise doit inclure les plans conformes \u00e0 l'ex\u00e9cution, les num\u00e9ros de s\u00e9rie, les sauvegardes des param\u00e8tres, les rapports des tests de protection, les tests des onduleurs et des circuits de d\u00e9rivation, les donn\u00e9es des tests d'autonomie, les alarmes, les rapports des tests de communication, les photographies des produits, le registre des preuves SABS et la matrice de garantie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-30013\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"14\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-30013\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> Qu'est-ce qu'un syst\u00e8me d'alimentation de secours industriel \u00e0 batterie (UPS) pour un a\u00e9roport en Afrique du Sud ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-30013\" class=\"elementor-element elementor-element-e934f84b e-con-full e-flex e-con e-child\" data-id=\"e934f84b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cedcaa5c elementor-widget elementor-widget-heading\" data-id=\"cedcaa5c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Industrial UPS battery backup combines energy storage, power conversion, online UPS equipment, bypass equipment and controls to keep approved airport critical loads supplied during a grid event. For this project, the electrical design starts from a 180 kVA three-phase load and a 380&#x2013;415 Vac supply.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-30014\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"15\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-30014\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> Comment un acheteur doit-il choisir un syst\u00e8me de stockage par batterie pour un onduleur d'a\u00e9roport de 180 kVA ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-30014\" class=\"elementor-element elementor-element-22223007 e-con-full e-flex e-con e-child\" data-id=\"22223007\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-40e65063 elementor-widget elementor-widget-heading\" data-id=\"40e65063\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Choisissez un syst\u00e8me en fonction de la puissance continue en kW, de la puissance de l'onduleur en kVA, de l'autonomie requise en courant alternatif, de la tension, du courant, des dimensions de la salle, du refroidissement, de la coordination des protections, du dossier de documentation, de la prise en charge de la garantie et de la r\u00e9ception lors de la mise en service. Le mod\u00e8le KRL-B522L offre une classe de produit d\u2019entr\u00e9e de gamme publi\u00e9e de 250 kW \/ 522 kWh pour la charge a\u00e9roportuaire indiqu\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-30015\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"16\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-30015\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> Quels documents SABS doivent figurer dans une proposition relative \u00e0 un syst\u00e8me de stockage par batteries UPS pour un a\u00e9roport ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-30015\" class=\"elementor-element elementor-element-21aaa558 e-con-full e-flex e-con e-child\" data-id=\"21aaa558\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-51b64e06 elementor-widget elementor-widget-heading\" data-id=\"51b64e06\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La proposition doit inclure un registre de conformit\u00e9 pr\u00e9cisant la norme applicable, l'organisme de normalisation, la dur\u00e9e de validit\u00e9 et les mod\u00e8les exacts concern\u00e9s. Ce registre doit correspondre \u00e0 la version finale du KRL relatif aux syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS), aux onduleurs en ligne (UPS), aux \u00e9quipements de d\u00e9rivation, aux enceintes et \u00e0 la nomenclature fournie \u00e0 l'a\u00e9roport.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Une offre technique ax\u00e9e sur les produits pour un projet d'alimentation sans coupure (UPS) en int\u00e9rieur dans un a\u00e9roport sud-africain, avec une charge triphas\u00e9e de 180 kVA, une alimentation de 380 \u00e0 415 V CA et une exigence de garantie d'un an couvrant l'ensemble du syst\u00e8me.<\/p>","protected":false},"author":9,"featured_media":12477,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[77,95,82],"tags":[917,916,919,92,915,918,920],"class_list":["post-12480","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-energy-storage","category-industry-application","tag-180-kva-ups","tag-airport-ups","tag-critical-power","tag-energy-storage","tag-industrial-ups-battery-backup","tag-krl-b522l","tag-south-africa"],"acf":[],"uagb_featured_image_src":{"full":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-South-Africa-Airport-UPS-180kVA-Cover.jpg",1400,788,false],"thumbnail":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-South-Africa-Airport-UPS-180kVA-Cover-150x150.jpg",150,150,true],"medium":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-South-Africa-Airport-UPS-180kVA-Cover-300x169.jpg",300,169,true],"medium_large":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-South-Africa-Airport-UPS-180kVA-Cover-768x432.jpg",768,432,true],"large":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-South-Africa-Airport-UPS-180kVA-Cover-1024x576.jpg",1024,576,true],"1536x1536":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-South-Africa-Airport-UPS-180kVA-Cover.jpg",1400,788,false],"2048x2048":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-South-Africa-Airport-UPS-180kVA-Cover.jpg",1400,788,false],"trp-custom-language-flag":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-South-Africa-Airport-UPS-180kVA-Cover.jpg",18,10,false],"woocommerce_thumbnail":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-South-Africa-Airport-UPS-180kVA-Cover-300x300.jpg",300,300,true],"woocommerce_single":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-South-Africa-Airport-UPS-180kVA-Cover-600x338.jpg",600,338,true],"woocommerce_gallery_thumbnail":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-South-Africa-Airport-UPS-180kVA-Cover-100x100.jpg",100,100,true]},"uagb_author_info":{"display_name":"KRL Power_LEI","author_link":"https:\/\/www.krlpower.com\/fr\/author\/krl-power_lei\/"},"uagb_comment_info":0,"uagb_excerpt":"A product-focused technical offer for a South African airport indoor UPS project with a 180 kVA three-phase load, a 380&#x2013;415 Vac supply, and a one-year whole-system warranty requirement.","_links":{"self":[{"href":"https:\/\/www.krlpower.com\/fr\/wp-json\/wp\/v2\/posts\/12480","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.krlpower.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.krlpower.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.krlpower.com\/fr\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/www.krlpower.com\/fr\/wp-json\/wp\/v2\/comments?post=12480"}],"version-history":[{"count":1,"href":"https:\/\/www.krlpower.com\/fr\/wp-json\/wp\/v2\/posts\/12480\/revisions"}],"predecessor-version":[{"id":12481,"href":"https:\/\/www.krlpower.com\/fr\/wp-json\/wp\/v2\/posts\/12480\/revisions\/12481"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.krlpower.com\/fr\/wp-json\/wp\/v2\/media\/12477"}],"wp:attachment":[{"href":"https:\/\/www.krlpower.com\/fr\/wp-json\/wp\/v2\/media?parent=12480"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.krlpower.com\/fr\/wp-json\/wp\/v2\/categories?post=12480"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.krlpower.com\/fr\/wp-json\/wp\/v2\/tags?post=12480"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}