{"id":12751,"date":"2026-09-05T10:00:00","date_gmt":"2026-09-05T10:00:00","guid":{"rendered":"https:\/\/www.krlpower.com\/?p=12751"},"modified":"2026-09-05T01:02:56","modified_gmt":"2026-09-05T01:02:56","slug":"suid-afrika-watter-krl-kaste-om-te-koop","status":"publish","type":"post","link":"https:\/\/www.krlpower.com\/af\/bess\/south-africa-which-krl-cabinet-to-buy\/","title":{"rendered":"Watter KRL-kas 'n Suid-Afrikaanse aanleg moet koop"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"12751\" class=\"elementor elementor-12751\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a840141 auto-article-root e-flex e-con-boxed e-con e-parent\" data-id=\"a840141\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2211b22d auto-image elementor-widget elementor-widget-image\" data-id=\"2211b22d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Liquid-Cooling-vs-Air-Cooling-Cover-1024x1024.jpg\" class=\"attachment-large size-large wp-image-12666\" alt=\"KRL-B261L 125 kW 261 kWh en KRL-B522L 250 kW 522 kWh vloeistofgekoelde kaste wat in die oorsig van verkoelingsmetodes gebruik is\" srcset=\"https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Liquid-Cooling-vs-Air-Cooling-Cover-1024x1024.jpg 1024w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Liquid-Cooling-vs-Air-Cooling-Cover-300x300.jpg 300w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Liquid-Cooling-vs-Air-Cooling-Cover-150x150.jpg 150w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Liquid-Cooling-vs-Air-Cooling-Cover-768x768.jpg 768w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Liquid-Cooling-vs-Air-Cooling-Cover-600x600.jpg 600w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Liquid-Cooling-vs-Air-Cooling-Cover-100x100.jpg 100w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Liquid-Cooling-vs-Air-Cooling-Cover.jpg 1080w\" sizes=\"(max-width: 1024px) 100vw, 1024px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-010a9fae auto-p elementor-widget elementor-widget-heading\" data-id=\"010a9fae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">South African plants rarely arrive at this choice by comparing cabinet capacities in isolation. The feeder sets the power limit; the operating window sets the energy requirement. Motor overlap, PV input and an existing diesel set can move the decision again. <strong><a href=\"https:\/\/www.krlpower.com\/af\/\" target=\"_blank\" style=\"color:#046bd2\">KRL Krag<\/a><\/strong> puts those functions in the same outdoor liquid-cooled product family, so the useful question is which cabinet still fits the plant as it operates today.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c13ddeaa auto-table elementor-widget elementor-widget-text-editor\" data-id=\"c13ddeaa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Plant condition<\/th><th>KRL product<\/th><th>Ratings that matter first<\/th><\/tr><\/thead><tbody><tr><td>Signed load around 80-120 kW and 189 A still holds<\/td><td>B261L<\/td><td>125 kW \/ 261 kWh \/ 189 A<\/td><\/tr><tr><td>Day overlap has moved into roughly 140-220 kW<\/td><td>B522L<\/td><td>250 kW \/ 522 kWh \/ 375 A<\/td><\/tr><tr><td>Signed load is 400 kW and up, or required energy is already 1.5-2 MWh<\/td><td>B2M6L family<\/td><td>750 \/ 1000 kW and 1.5 \/ 2 MWh<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-412d480f auto-p elementor-widget elementor-widget-heading\" data-id=\"412d480f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">The table is only a starting point. Plants can sit below 125 kW most of the day and still outgrow B261L when several motors close together. Another site may have comfortable current headroom but need more stored energy through the night.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5fecb91e auto-h2 elementor-widget elementor-widget-heading\" data-id=\"5fecb91e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">B261L fits the smaller process hall until the feeder says otherwise<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7f9aadb1 auto-p elementor-widget elementor-widget-heading\" data-id=\"7f9aadb1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Load shedding may hit in the afternoon, but the cabinet still has to carry the actual signed list: process controls, lighting and the motors allowed to overlap.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e86034a auto-p elementor-widget elementor-widget-heading\" data-id=\"8e86034a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">One hall might run near 80-120 kW. Starts remain controlled and 189 A is still enough on the incoming path. That is the natural range for the <strong><a href=\"https:\/\/www.krlpower.com\/af\/battery\/krl-b261l-125kw-261kwh\/\" target=\"_blank\" style=\"color:#046bd2\">KRL-B261L 125 kW \/ 261 kWh<\/a><\/strong>, model KRL-B261L-125H3S-120M1-HX1.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4da4eec3 auto-p elementor-widget elementor-widget-heading\" data-id=\"4da4eec3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Its published figures are 125 kW AC power on-grid and off-grid, 189 A current, 261 kWh rated energy and 120 kW PV input. The battery is LiFePO4 at 832 V and 314 Ah. KRL also lists liquid cooling, a diesel port, under-10 ms switching, RS485 \/ WiFi, IP65 battery protection, altitude under 2000 m and parallel operation up to 10 units. Cabinet mass is about 2600 kg.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34096863 auto-p elementor-widget elementor-widget-heading\" data-id=\"34096863\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">The energy number is easy to misread. At 125 kW, 261 kWh works out to roughly two hours on paper. An 80 kW signed load lasts longer. Full-power operation through an eight-hour night does not fit that energy class.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0d2a66a6 auto-p elementor-widget elementor-widget-heading\" data-id=\"0d2a66a6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Current can become the harder limit first. Two dryers starting close together may push the site beyond 189 A even if the normal running load looks modest. At that point the smaller cabinet is short on feeder duty, not necessarily short on energy.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-64c8f696 auto-p elementor-widget elementor-widget-heading\" data-id=\"64c8f696\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Liquid cooling and the diesel port are useful because they are already part of the cabinet specification. Plants with a generator in the yard do not need a separate product family just to keep that interface available.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eafae792 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"eafae792\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">B522L makes sense once the 125 kW cabinet starts getting crowded<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-909a485a auto-image elementor-widget elementor-widget-image\" data-id=\"909a485a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/09\/KRL-Peak-Shaving-and-Backup-Inquiry-Checklist-1024x768.jpg\" class=\"attachment-large size-large wp-image-12728\" alt=\"KRL C&amp;I cabinet inquiry checklist for primary duty peak window outage reserve PV diesel and transformer data\" srcset=\"https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/09\/KRL-Peak-Shaving-and-Backup-Inquiry-Checklist-1024x768.jpg 1024w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/09\/KRL-Peak-Shaving-and-Backup-Inquiry-Checklist-300x225.jpg 300w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/09\/KRL-Peak-Shaving-and-Backup-Inquiry-Checklist-768x576.jpg 768w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/09\/KRL-Peak-Shaving-and-Backup-Inquiry-Checklist-16x12.jpg 16w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/09\/KRL-Peak-Shaving-and-Backup-Inquiry-Checklist-600x450.jpg 600w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/09\/KRL-Peak-Shaving-and-Backup-Inquiry-Checklist.jpg 1448w\" sizes=\"(max-width: 1024px) 100vw, 1024px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2b2dbc6a auto-p elementor-widget elementor-widget-heading\" data-id=\"2b2dbc6a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Second production lines, extra cooling or a charger bay can move afternoon overlap into the 140-220 kW range. The problem is no longer theoretical once the load is regularly leaning on the 125 kW limit.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3b65395c auto-p elementor-widget elementor-widget-heading\" data-id=\"3b65395c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die <strong><a href=\"https:\/\/www.krlpower.com\/af\/battery\/krl-b522l-250kw-522kwh\/\" target=\"_blank\" style=\"color:#046bd2\">KRL-B522L 250 kW \/ 522 kWh<\/a><\/strong> moves the site to one 250 kW converter and a 375 A current class. The order model is KRL-B522L-250H3S-240M2-HX1.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0eeb3d02 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"0eeb3d02\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Parameter<\/th><th>B522L<\/th><\/tr><\/thead><tbody><tr><td>Rated energy<\/td><td>522 kWh<\/td><\/tr><tr><td>AC power<\/td><td>250 kW<\/td><\/tr><tr><td>Current<\/td><td>375 A<\/td><\/tr><tr><td>Battery<\/td><td>LiFePO4, 832 V, 628 Ah<\/td><\/tr><tr><td>PV-inset<\/td><td>240 kW<\/td><\/tr><tr><td>Afkoeling<\/td><td>Battery liquid cooling<\/td><\/tr><tr><td>Diesel port<\/td><td>Ja<\/td><\/tr><tr><td>Oorskakel<\/td><td>Under 10 ms<\/td><\/tr><tr><td>Parallel<\/td><td>6<\/td><\/tr><tr><td>Massa<\/td><td>About 4900 kg<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-63256fd5 auto-p elementor-widget elementor-widget-heading\" data-id=\"63256fd5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Two B261L cabinets can also provide two 125 kW converters, but the result is not the same installation. B522L puts the 250 kW duty on one converter, one 375 A path and one roughly 4.9 t cabinet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-72030f05 auto-p elementor-widget elementor-widget-heading\" data-id=\"72030f05\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">The roof can push the project in the same direction. B261L publishes 120 kW PV input; B522L publishes 240 kW. Sites that need the larger solar input can use the <strong><a href=\"https:\/\/www.krlpower.com\/af\/bess\/522kwh-250kw-solar-storage-diesel-microgrid-cabinet-an-industrial-grade-energy-hub\/\" target=\"_blank\" style=\"color:#046bd2\">522 kWh \/ 250 kW solar-storage-diesel cabinet<\/a><\/strong> as the relevant configuration.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2d089035 auto-p elementor-widget elementor-widget-heading\" data-id=\"2d089035\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">KRL lists parallel operation up to six B522L units. That gives the plant room to add another 250 kW block later without pretending that future expansion has to be installed on day one.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60c2bbf0 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"60c2bbf0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Plant-scale loads call for a different piece of equipment<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d39134ef auto-image elementor-widget elementor-widget-image\" data-id=\"d39134ef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-B261L-B522L-Cooling-Selection-1024x768.jpg\" class=\"attachment-large size-large wp-image-12668\" alt=\"KRL-B261L 125 kW 261 kWh compared with KRL-B522L 250 kW 522 kWh after liquid cooling is selected\" srcset=\"https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-B261L-B522L-Cooling-Selection-1024x768.jpg 1024w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-B261L-B522L-Cooling-Selection-300x225.jpg 300w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-B261L-B522L-Cooling-Selection-768x576.jpg 768w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-B261L-B522L-Cooling-Selection-1536x1152.jpg 1536w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-B261L-B522L-Cooling-Selection-600x450.jpg 600w, https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-B261L-B522L-Cooling-Selection.jpg 1600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0fdb47a7 auto-p elementor-widget elementor-widget-heading\" data-id=\"0fdb47a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Sites already carrying 400 kW or more, or needing 1.5-2 MWh through the operating window, are no longer dealing with the same installation problem. Several small cabinets mean several lifts, more cable runs and more repeated interfaces around the yard.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5153544c auto-p elementor-widget elementor-widget-heading\" data-id=\"5153544c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">KRL's larger route is the <strong><a href=\"https:\/\/www.krlpower.com\/af\/battery\/krl-b2m6l-1-2mw-2-6mwh\/\" target=\"_blank\" style=\"color:#046bd2\">KRL-B2M6L<\/a><\/strong> family:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ab36126a auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"ab36126a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>750 kW \/ 1.5 MWh:<\/strong> KRL-B1M5L-750H3S-720M6-HX1, 1130 A, 720 kW PV, about 15 t<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>1000 kW \/ 2 MWh:<\/strong> KRL-B2ML-1MH3S-960M8-HX1, 1500 A, 960 kW PV, about 19.5 t<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Container:<\/strong> 6058 &#xD7; 2438 &#xD7; 2896 mm<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-72b3f77d auto-p elementor-widget elementor-widget-heading\" data-id=\"72b3f77d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Those numbers change the job around the storage system. The current path rises to 1130 A or 1500 A. PV input rises to 720 kW or 960 kW. The equipment itself becomes a roughly 15 t or 19.5 t plant item in a 20-ft box.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5bfc2cf2 auto-p elementor-widget elementor-widget-heading\" data-id=\"5bfc2cf2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Sites examining storage mainly around Eskom bill reduction can continue with the <strong><a href=\"https:\/\/www.krlpower.com\/af\/bess\/south-africa-eskom-bill-reduction-2mwh-ci-energy-storage-system\/\" target=\"_blank\" style=\"color:#046bd2\">2 MWh C&amp;I energy storage system<\/a><\/strong>. Plants whose signed duty has already reached the 1 MW class can use the <strong><a href=\"https:\/\/www.krlpower.com\/af\/bess\/south-africa-factory-energy-storage-solution-1mw-2mwh-ess\/\" target=\"_blank\" style=\"color:#046bd2\">1 MW \/ 2 MWh factory backup system<\/a><\/strong> as the closer reference.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f206e170 auto-p elementor-widget elementor-widget-heading\" data-id=\"f206e170\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Liquid cooling, diesel connection, under-10 ms switching and RS485 \/ WiFi remain part of the same family. What changes most is the scale of the electrical and civil work around the unit.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2d5890df auto-h2 elementor-widget elementor-widget-heading\" data-id=\"2d5890df\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Put the reason for the model choice on the order<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-555d34b9 auto-p elementor-widget elementor-widget-heading\" data-id=\"555d34b9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Purchase lines are easier to defend when the selected model can be tied to one or two site limits instead of a vague preference for more capacity.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-73faf17b auto-table elementor-widget elementor-widget-text-editor\" data-id=\"73faf17b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Site evidence<\/th><th>Product path<\/th><th>Purchase check<\/th><\/tr><\/thead><tbody><tr><td>80-120 kW signed load, motor overlap stays within 189 A, energy duty remains short<\/td><td>B261L<\/td><td>125 kW \/ 261 kWh \/ 189 A<\/td><\/tr><tr><td>140-220 kW overlap, 189 A no longer holds, or the roof needs the larger PV port<\/td><td>B522L<\/td><td>250 kW \/ 522 kWh \/ 375 A \/ 240 kW PV<\/td><\/tr><tr><td>Plant duty is already hundreds of kW and energy has reached 1.5-2 MWh<\/td><td>B2M6L family<\/td><td>750 or 1000 kW, 1130 or 1500 A, 1.5 or 2 MWh<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c8ab7c32 auto-p elementor-widget elementor-widget-heading\" data-id=\"c8ab7c32\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">The full outdoor range is listed under <strong><a href=\"https:\/\/www.krlpower.com\/af\/batterye\/ci-energy-storage-system\/\" target=\"_blank\" style=\"color:#046bd2\">KRL C&amp;I-energiebergingstelsels<\/a><\/strong>. Broader model comparison is covered in the <strong><a href=\"https:\/\/www.krlpower.com\/af\/bess\/hoe-om-n-kommersiele-energiestoorstelsel-te-kies\/\" target=\"_blank\" style=\"color:#046bd2\">Keuse-gids vir kommersi\u00eble en industri\u00eble energiestoorstelsels<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dfcbebd4 auto-p elementor-widget elementor-widget-heading\" data-id=\"dfcbebd4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Diesel-heavy sites can continue with <strong><a href=\"https:\/\/www.krlpower.com\/af\/bess\/industrial-battery-storage-for-diesel-cost\/\" target=\"_blank\" style=\"color:#046bd2\">Industri\u00eble batterystoor vir dieselkostevermindering<\/a><\/strong>. Plants sizing around an overnight stoppage can use <strong><a href=\"https:\/\/www.krlpower.com\/af\/bess\/factory-blackout-at-2-a-m-protect-your-production-line\/\" target=\"_blank\" style=\"color:#046bd2\">2 a.m. factory blackout recovery<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4ef8478d e-con-full auto-faq e-flex e-con e-child\" data-id=\"4ef8478d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5189c21c elementor-widget elementor-widget-heading\" data-id=\"5189c21c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">V&amp;A<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e0f84f86 elementor-widget elementor-widget-n-accordion\" data-id=\"e0f84f86\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings='{\"default_state\":\"all_collapsed\",\"max_items_expended\":\"one\",\"n_accordion_animation_duration\":{\"unit\":\"ms\",\"size\":400,\"sizes\":[]}}' data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accordeon. Open skakels met Enter of Spasie, sluit met Escape en navigeer met die pyltoetssleutels.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3770\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3770\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> What should be checked before ordering B261L? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3770\" class=\"elementor-element elementor-element-1f77a9f8 e-con-full e-flex e-con e-child\" data-id=\"1f77a9f8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-69408355 elementor-widget elementor-widget-heading\" data-id=\"69408355\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">Check the signed running load, the motors allowed to start together, the 189 A path and the number of hours the selected load must stay on battery.<\/span>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3771\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3771\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> Can a hall below 125 kW still be too large for B261L? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3771\" class=\"elementor-element elementor-element-a36f6a0c e-con-full e-flex e-con e-child\" data-id=\"a36f6a0c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-30d150e8 elementor-widget elementor-widget-heading\" data-id=\"30d150e8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">Yes. Normal running power may stay below 125 kW while overlapping starts push current past 189 A.<\/span>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3772\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3772\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> How long can 261 kWh carry the load? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3772\" class=\"elementor-element elementor-element-74b0b0ca e-con-full e-flex e-con e-child\" data-id=\"74b0b0ca\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7986d95a elementor-widget elementor-widget-heading\" data-id=\"7986d95a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">Roughly two hours at 125 kW on paper. Lower signed load extends that time; an eight-hour full-power night does not fit this energy class.<\/span>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3773\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3773\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> What changes with B522L? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3773\" class=\"elementor-element elementor-element-dc95f015 e-con-full e-flex e-con e-child\" data-id=\"dc95f015\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-49de7816 elementor-widget elementor-widget-heading\" data-id=\"49de7816\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">AC power rises to 250 kW, current to 375 A, rated energy to 522 kWh and PV input to 240 kW.<\/span>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3774\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3774\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> Why use one B522L instead of two B261L cabinets? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3774\" class=\"elementor-element elementor-element-a588a33f e-con-full e-flex e-con e-child\" data-id=\"a588a33f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2f76930a elementor-widget elementor-widget-heading\" data-id=\"2f76930a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">One B522L puts the 250 kW duty on one converter, one 375 A path and one approximately 4.9 t cabinet.<\/span>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3775\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3775\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> Can the PV side determine the model? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3775\" class=\"elementor-element elementor-element-8303f92b e-con-full e-flex e-con e-child\" data-id=\"8303f92b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bb41af5a elementor-widget elementor-widget-heading\" data-id=\"bb41af5a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">Yes. B261L publishes 120 kW PV input and B522L publishes 240 kW, so a larger roof can outgrow the smaller PV port before the battery energy becomes the main issue.<\/span>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3776\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3776\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> Is a diesel connection listed? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3776\" class=\"elementor-element elementor-element-0faa771a e-con-full e-flex e-con e-child\" data-id=\"0faa771a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4acd69db elementor-widget elementor-widget-heading\" data-id=\"4acd69db\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">Yes. The published product data lists a diesel port on B261L, B522L and both B2M6L strings.<\/span>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3777\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3777\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> What does the under-10 ms figure describe? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3777\" class=\"elementor-element elementor-element-47724d50 e-con-full e-flex e-con e-child\" data-id=\"47724d50\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ab367b70 elementor-widget elementor-widget-heading\" data-id=\"ab367b70\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">It is KRL's published changeover figure for this outdoor product family.<\/span>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3778\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3778\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> Can capacity be added later? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3778\" class=\"elementor-element elementor-element-e86645ef e-con-full e-flex e-con e-child\" data-id=\"e86645ef\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a56c23e1 elementor-widget elementor-widget-heading\" data-id=\"a56c23e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">B261L lists parallel operation up to 10 units. B522L lists up to 6.<\/span>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3779\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3779\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> What should the lifting plan allow for? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3779\" class=\"elementor-element elementor-element-e30935c1 e-con-full e-flex e-con e-child\" data-id=\"e30935c1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-496a3f52 elementor-widget elementor-widget-heading\" data-id=\"496a3f52\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">About 2600 kg for B261L, about 4900 kg for B522L, and roughly 15 t or 19.5 t for the two B2M6L strings.<\/span>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-37710\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-37710\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> When has the project moved beyond the smaller cabinet class? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-37710\" class=\"elementor-element elementor-element-219cc484 e-con-full e-flex e-con e-child\" data-id=\"219cc484\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6e022917 elementor-widget elementor-widget-heading\" data-id=\"6e022917\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">Signed load around 400 kW and above, or an energy requirement already in the 1.5-2 MWh range, puts the site into the larger KRL product path.<\/span>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-37711\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-37711\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> Which B2M6L combinations are published here? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-37711\" class=\"elementor-element elementor-element-a7670c9c e-con-full e-flex e-con e-child\" data-id=\"a7670c9c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cf4c1d63 elementor-widget elementor-widget-heading\" data-id=\"cf4c1d63\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">The listed strings are 750 kW \/ 1.5 MWh and 1000 kW \/ 2 MWh.<\/span>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-37712\" class=\"e-n-accordion-item\">\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-37712\">\n\t\t\t\t\t<span class=\"e-n-accordion-item-title-header\"><div class=\"e-n-accordion-item-title-text\"> What current comes with those larger strings? <\/div><\/span>\n\t\t\t\t\t\t\t<span class=\"e-n-accordion-item-title-icon\">\n\t\t\t<span class=\"e-opened\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class=\"e-closed\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-37712\" class=\"elementor-element elementor-element-4917a949 e-con-full e-flex e-con e-child\" data-id=\"4917a949\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cb7b51ee elementor-widget elementor-widget-heading\" data-id=\"cb7b51ee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">The 750 kW string lists 1130 A. The 1000 kW string lists 1500 A.<\/span>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Suid-Afrikaanse kragstasies kan kies tussen KRL-B261L, KRL-B522L en die B2M6L-familie deur die ondertekende las, stroom, energielasting, PV-inset en kragstasieskaal op mekaar af te stem.<\/p>","protected":false},"author":9,"featured_media":12666,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[77,95,82],"tags":[548,324,125,878,931,918,1012],"class_list":["post-12751","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-energy-storage","category-industry-application","tag-commercial-battery-storage","tag-industrial-energy-storage","tag-krl-power","tag-krl-b261l","tag-krl-b2m6l","tag-krl-b522l","tag-south-africa-ci-bess"],"acf":[],"uagb_featured_image_src":{"full":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Liquid-Cooling-vs-Air-Cooling-Cover.jpg",1080,1080,false],"thumbnail":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Liquid-Cooling-vs-Air-Cooling-Cover-150x150.jpg",150,150,true],"medium":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Liquid-Cooling-vs-Air-Cooling-Cover-300x300.jpg",300,300,true],"medium_large":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Liquid-Cooling-vs-Air-Cooling-Cover-768x768.jpg",768,768,true],"large":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Liquid-Cooling-vs-Air-Cooling-Cover-1024x1024.jpg",1024,1024,true],"1536x1536":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Liquid-Cooling-vs-Air-Cooling-Cover.jpg",1080,1080,false],"2048x2048":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Liquid-Cooling-vs-Air-Cooling-Cover.jpg",1080,1080,false],"trp-custom-language-flag":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Liquid-Cooling-vs-Air-Cooling-Cover.jpg",12,12,false],"woocommerce_thumbnail":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Liquid-Cooling-vs-Air-Cooling-Cover-300x300.jpg",300,300,true],"woocommerce_single":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Liquid-Cooling-vs-Air-Cooling-Cover-600x600.jpg",600,600,true],"woocommerce_gallery_thumbnail":["https:\/\/www.krlpower.com\/wp-content\/uploads\/2026\/08\/KRL-Liquid-Cooling-vs-Air-Cooling-Cover-100x100.jpg",100,100,true]},"uagb_author_info":{"display_name":"KRL Power_LEI","author_link":"https:\/\/www.krlpower.com\/af\/author\/krl-power_lei\/"},"uagb_comment_info":0,"uagb_excerpt":"South African plants can choose between KRL-B261L, KRL-B522L and the B2M6L family by matching signed load, current, energy duty, PV input and plant scale.","_links":{"self":[{"href":"https:\/\/www.krlpower.com\/af\/wp-json\/wp\/v2\/posts\/12751","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.krlpower.com\/af\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.krlpower.com\/af\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.krlpower.com\/af\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/www.krlpower.com\/af\/wp-json\/wp\/v2\/comments?post=12751"}],"version-history":[{"count":1,"href":"https:\/\/www.krlpower.com\/af\/wp-json\/wp\/v2\/posts\/12751\/revisions"}],"predecessor-version":[{"id":12752,"href":"https:\/\/www.krlpower.com\/af\/wp-json\/wp\/v2\/posts\/12751\/revisions\/12752"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.krlpower.com\/af\/wp-json\/wp\/v2\/media\/12666"}],"wp:attachment":[{"href":"https:\/\/www.krlpower.com\/af\/wp-json\/wp\/v2\/media?parent=12751"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.krlpower.com\/af\/wp-json\/wp\/v2\/categories?post=12751"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.krlpower.com\/af\/wp-json\/wp\/v2\/tags?post=12751"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}